Simplifies commissioning through onboard advanced diagnostics, including a node-specific H1 bus oscilloscope trace that can be viewed within the RSLogix5000 Add-On Profile
Use with the 1786-RPFS repeater
Self-contained, panel, or DIN-rail mountable device
Includes 200 micron cable
Provides trunk open-circuit and short-circuit monitoring and reroutes trunk connections for extended availability
Links an EtherNet/IPâ„¢ network to a single H1 segment
Supports FDT/DTM Technology, allowing direct access to field device diagnostics and parameters using an FDT frame, such as FactoryTalk® AssetCentre
Links an EtherNet/IPâ„¢ network to a single Profibus-PA segment
Provides seamless RSLogix 5000â„¢ environment integration through Add-On Profiles, which automatically identifies field devices and configures them to their default settings
Connects and powers as many as 16 field devices, eliminating the need for external power conditioners
Provides seamless RSLogix5000â„¢ integration through Add-On Profiles, which automatically identifies field devices and configures them to their default settings
Supports ControlNet Media redundancy
Use a repeater adapter to supply a maximum of 1.6 A @ 5V DC of current to power the repeater modules
Protects the integrity of a FOUNDATION Fieldbus H1 or Profibus-PA segment by automatically isolating faulty drops and restoring power when faults are corrected
Provides all basic diagnostic information in the input assembly
Simplifies commissioning through onboard advanced diagnostics, including a node-specific PA bus oscilloscope trace that can be viewed within the RSLogix5000 Add-On Profile
Operates as a true PA master without requiring a DP network, DP master, coupler device, or external power conditioner
Links an ControlNetâ„¢ network to a single Profibus-PA segment
Links a ControlNetâ„¢ network to a single H1 segment
Supports as many as 24 PA field devices
Displays useful field bus diagnostic information via status LEDs
Supports EtherNet/IP Media redundancy
Supports multiple levels of device and media redundancy
Helps simplify large network commissioning through diagnostic parameters such as Power Supply Voltage, PA Bus Voltage (A & B bus), PA Bus Current (A & B bus), and Unit Internal Temperature
Helps simplify large network commissioning through diagnostic parameters such as Power Supply Voltage, H1 Bus Voltage (A & B bus), H1 Bus Current (A & B bus), and Unit Internal Temperature
Supports Master Device redundancy
Contains the FOUNDATION Fieldbus Registered FF H1 Stack developed by Rockwell Automation®