Supports Master Device redundancy
Provides trunk open-circuit and short-circuit monitoring and reroutes trunk connections for extended availability
Use with the 1786-RPFS repeater
Self-contained, panel, or DIN-rail mountable device
Supports FDT/DTM Technology, allowing direct access to field device diagnostics and parameters using an FDT frame, such as FactoryTalk® AssetCentre
Contains the FOUNDATION Fieldbus Registered FF H1 Stack developed by Rockwell Automation®
Links a ControlNetâ„¢ network to a single H1 segment
Helps simplify large network commissioning through diagnostic parameters such as Power Supply Voltage, PA Bus Voltage (A & B bus), PA Bus Current (A & B bus), and Unit Internal Temperature
Supports as many as 24 PA field devices
Includes 200 micron cable
Links an EtherNet/IPâ„¢ network to a single H1 segment
Links an ControlNetâ„¢ network to a single Profibus-PA segment
Operates as a true PA master without requiring a DP network, DP master, coupler device, or external power conditioner
Supports EtherNet/IP Media redundancy
Simplifies commissioning through onboard advanced diagnostics, including a node-specific H1 bus oscilloscope trace that can be viewed within the RSLogix5000 Add-On Profile
Provides all basic diagnostic information in the input assembly
Simplifies commissioning through onboard advanced diagnostics, including a node-specific PA bus oscilloscope trace that can be viewed within the RSLogix5000 Add-On Profile
Use a repeater adapter to supply a maximum of 1.6 A @ 5V DC of current to power the repeater modules
Supports ControlNet Media redundancy
Connects and powers as many as 16 field devices, eliminating the need for external power conditioners
Provides seamless RSLogix 5000â„¢ environment integration through Add-On Profiles, which automatically identifies field devices and configures them to their default settings
Links an EtherNet/IPâ„¢ network to a single Profibus-PA segment
Helps simplify large network commissioning through diagnostic parameters such as Power Supply Voltage, H1 Bus Voltage (A & B bus), H1 Bus Current (A & B bus), and Unit Internal Temperature
Provides seamless RSLogix5000â„¢ integration through Add-On Profiles, which automatically identifies field devices and configures them to their default settings
Displays useful field bus diagnostic information via status LEDs
Protects the integrity of a FOUNDATION Fieldbus H1 or Profibus-PA segment by automatically isolating faulty drops and restoring power when faults are corrected
Supports multiple levels of device and media redundancy